Town of Cary Construction Detail Drawings - Effective 8/23/07

The following detail drawings are available in PDF, DWG, and JPG format. You will need Adobe Reader to view the PDF files. The DWG files are in Autocad 2000 format.

Download a ZIP file with all drawings: All PDFs (12 MB) | All DWGs (17 MB) | All JPGs (21 MB)

PDF DWG JPG Sheet
Section 03000 Streets
PDF DWG JPG 03000.01 (1 of 3) Standard major collector street typical section
PDF DWG JPG 03000.01 (2 of 3) Standard minor collector street typical section
PDF DWG JPG 03000.01 (3 of 3) Standard local street typical section
PDF DWG JPG 03000.02 (1 of 1) Standard concrete curb and gutter
PDF DWG JPG 03000.03 (1 of 1) Standard section without curb and gutter
PDF DWG JPG 03000.04 (1 of 1) Standard shoulder section witdout sidewalk
PDF DWG JPG 03000.05 (1 of 1) Standard utility locations in street
PDF DWG JPG 03000.06 (1 of 2) Residential CUL-DE-SAC dimensions
PDF DWG JPG 03000.06 (2 of 2) CUL-DE-SAC dimensions
PDF DWG JPG 03000.07 (1 of 1) Standard concrete sidewalk
PDF DWG JPG 03000.08 (1 of 1) Standard multi-use path
PDF DWG JPG 03000.09 (1 of 1) Standard right in/right out channelization (limited frontage)
PDF DWG JPG 03000.10 (1 of 1) Standard Method of Removing Existing Curb (for driveway apron installation)
PDF DWG JPG 03000.11 (1 of 1) Standard method of ending curb and gutter
PDF DWG JPG 03000.12 (1 of 1) Standard curb drain
PDF DWG JPG 03000.13 (1 of 1) Standard driveway apron
PDF DWG JPG 03000.14 (1 of 3) Standard wheelchair ramp
PDF DWG JPG 03000.14 (2 of 3) Standard wheelchair ramp
PDF DWG JPG 03000.14 (3 of 3) Standard wheelchair ramp
PDF DWG JPG 03000.15 (1 of 1) Standard Pavement widening taper & markings
PDF DWG JPG 03000.16 (1 of 1) Temporary barricade for dead end roads
PDF DWG JPG 03000.17 (1 of 1) Precast concrete pedestrian/bicycle underpass
PDF DWG JPG 03000.18 (1 of 3) Standard pavement undulation (parabolic speed hump)
PDF DWG JPG 03000.18 (2 of 3) Standard pavement undulation (flat top speed hump)
PDF DWG JPG 03000.18 (3 of 3) Standard pavement undulation (raised pedestrian crosswalk)
Section 04000 Soil Erosion, Sedimentation Control, and Landscaping
PDF DWG JPG 04000.01 (1 of 1) Standard temporary silt fence
PDF DWG JPG 04000.02 (1 of 1) Standard riser-barrel sediment basin (with skimmer)
PDF DWG JPG 04000.03 (1 of 2) Standard gravel & rip rap filter basin
PDF DWG JPG 04000.03 (2 of 2) Standard gravel & rip rap filter basin
PDF DWG JPG 04000.04 (1 of 1) (Existing Pipe Inverts) Gravel & rip rap filter berm basin
PDF DWG JPG 04000.05 (1 of 1) Catch basin riser/filter
PDF DWG JPG 04000.06 (1 of 1) Standard check dam
PDF DWG JPG 04000.07 (1 of 1) Standard construction entrance
PDF DWG JPG 04000.08 (1 of 1) Standard residential construction entrance
PDF DWG JPG 04000.09 (1 of 1) Standard diversion ditch
PDF DWG JPG 04000.10 (1 of 1) Standard rip rap lined channels
PDF DWG JPG 04000.11 (1 of 2) Standard temporary stream crossing
PDF DWG JPG 04000.11 (2 of 2) Standard temporary stream crossing
PDF DWG JPG 04000.12 (1 of 1) Standard pipe inlet protection (plywood & stone)
PDF DWG JPG 04000.13 (1 of 1) Standard block & gravel drop inlet protection
PDF DWG JPG 04000.14 (1 of 1) Standard catch basin/yard inlet protection
PDF DWG JPG 04000.15 (1 of 1) Standard construction exit wash rack
PDF DWG JPG 04000.16 (1 of 1) Standard temporary silt ditch
PDF DWG JPG 04000.17 (1 of 1) Standard rock dam detail
PDF DWG JPG 04000.18 (1 of 1) Standard skimmer detail
PDF DWG JPG 04000.19 (1 of 1) Standard inlet sediment control device
PDF DWG JPG 04000.20 (1 of 1) Pipe outlet to flat area no well-defined channel
PDF DWG JPG 04000.21 (1 of 1) Pipe outlet to well-defined channel
PDF DWG JPG 04000.22 (1 of 2) Standard level spreader
PDF DWG JPG 04000.22 (2 of 2) Standard level spreader (cross section)
Section 05000 Pipe Trenches
PDF DWG JPG 05000.01 (1 of 1) Standard trench and pavement repair sections
PDF DWG JPG 05000.02 (1 of 1) Carrier pipe
PDF DWG JPG 05000.03 (1 of 1) Carrier pipe - under railroad
Section 06000 Water Distribution Systems
PDF DWG JPG 06000.01 (1 of 2) Standard 3/4" water service & meter box installation
PDF DWG JPG 06000.01 (2 of 2) Standard 1"water service & meter box installation
PDF DWG JPG 06000.02 (1 of 1) Standard 1-1/2" & 2" meter installation & vault
PDF DWG JPG 06000.03 (1 of 1) Standard 3" & 4" meter installation & vault
PDF DWG JPG 06000.04 (1 of 1) Standard multiple branch service
PDF DWG JPG 06000.05 (1 of 1) Standard combined fire & domestic water service
PDF DWG JPG 06000.06 (1 of 1) Standard hydrant installation
PDF DWG JPG 06000.07 (1 of 2) Standard hydrant location
PDF DWG JPG 06000.07 (2 of 2) Standard hydrant location (for parking lot)
PDF DWG JPG 06000.08 (1 of 2) Standard valve box installation
PDF DWG JPG 06000.08 (2 of 2) Standard valve box installation
PDF DWG JPG 06000.09 (1 of 1) Standard valve rodding
PDF DWG JPG 06000.10 (1 of 2) Butterfly valve assembly for water valves deeper than 5-ft
PDF DWG JPG 06000.10 (2 of 2) Butterfly valve assembly for water valve 5-ft or less in depth
PDF DWG JPG 06000.11 (1 of 1) Standard 2" blow-off assembly
PDF DWG JPG 06000.12 (1 of 1) Standard capping detail
PDF DWG JPG 06000.13 (1 of 1) Standard reaction blocking
PDF DWG JPG 06000.14 (1 of 1) Standard thrust collar installation
PDF DWG JPG 06000.15 (1 of 2) Standard combination air valve manhole (for water, reclaimed water, or sewer mains)
PDF DWG JPG 06000.15 (2 of 2) Standard combination air valve manhole offset from main (for water, reclaimed water, or sewer mains)
PDF DWG JPG 06000.16 (1 of 1) Standard yard hydrant (non-freeze)
PDF DWG JPG 06000.17 (1 of 1) Standard sprinkler riser
PDF DWG JPG 06000.18 (1 of 1) Curb side fire department connection
PDF DWG JPG 06000.19 (1 of 1) Standard tapping sleeve & post indicator valve
Section 06200 Cross Connection Control
PDF DWG JPG 06200.01 Standard typical irrigation service connections
PDF DWG JPG 06200.02 Standard ¾ to 1 inch residential irrigation back flow assembly
PDF DWG JPG 06200.03 Standard ¾ to 2 inch commercial outdoor back flow assembly
PDF DWG JPG 06200.04 Standard ¾ to 2 inch commercial indoor back flow assembly
PDF DWG JPG 06200.05 Standard commercial outdoor back flow assembly (2 ½ inch diameter and larger)
PDF DWG JPG 06200.06 Standard commercial indoor backflow assembly (2 ½ inch diameter and larger)
Section 06500 Reclaimed water distribution Systems
PDF DWG JPG 06500.01 (1 of 1) Standard typical reclaimed water service connections
PDF DWG JPG 06500.02 (1 of 1) Standard ¾" water service & meter box installation (for reclaimed water service)
PDF DWG JPG 06500.03 (1 of 1) Standard reclaimed water hose bib and box
PDF DWG JPG 06500.04 (1 of 1) Standard reclaimed water 2" blow-off assembly
PDF DWG JPG 06500.05 (1 of 1) Reclaimed water manhole
PDF DWG JPG 06500.06 (1 of 2) Valve box installation (reclaimed water)
PDF DWG JPG 06500.06 (2 of 2) Valve box installation (reclaimed water)
PDF DWG JPG 06500.07 (1 of 1) Reclaimed water gate valve assembly
Section 07000 Sanitary Sewer
PDF DWG JPG 07000.01 (1 of 1) Standard precast concrete manhole
PDF DWG JPG 07000.02 (1 of 1) Manhole steps
PDF DWG JPG 07000.03 (1 of 3) Standard manhole ring and cover (type 1 paved areas)
PDF DWG JPG 07000.03 (2 of 3) Standard manhole ring and cover (type 2 for outfalls or unpaved areas)
PDF DWG JPG 07000.03 (3 of 3) Standard manhole ring and cover (type 3 for watertight manholes)
PDF DWG JPG 07000.04 (1 of 1) Standard typical manhole vent
PDF DWG JPG 07000.05 (1 of 1) Standard manhole ring and cover encasement
PDF DWG JPG 07000.06 (1 of 1) Standard outside drop manhole
PDF DWG JPG 07000.07 (1 of 1) Standard inside drop manhole
PDF DWG JPG 07000.08 (1 of 1) Standard inside drop for sanitary sewer service
PDF DWG JPG 07000.09 (1 of 1) Standard high velocity manhole invert
PDF DWG JPG 07000.10 (1 of 2) Standard sanitary sewer tap and service
PDF DWG JPG 07000.10 (2 of 2) Standard sanitary sewer service line (crossing common open space)
PDF DWG JPG 07000.11 (1 of 1) Standard sanitary sewer lateral connections
PDF DWG JPG 07000.12 (1 of 1) Cleanout cover assembly traffic area
PDF DWG JPG 07000.13 (1 of 1) Bedding for flexible & semi-rigid sanitary sewer pipe
PDF DWG JPG 07000.14 (1 of 1) Standard concrete encasement for stream crossing
PDF DWG JPG 07000.15 (1 of 2) Standard aerial crossing
PDF DWG JPG 07000.15 (2 of 2) Standard aerial crossing (8' maximum)
PDF DWG JPG 07000.16 (1 of 1) Standard air test table
PDF DWG JPG 07000.17 (1 of 1) Sanitary sewer protection during construction
PDF DWG JPG 07000.18 (1 of 1) Standard typical sewer point repair
Section 07500 Wastewater Pumping Systems
PDF DWG JPG 07500.01 (1 of 1) Pump station site layout
PDF DWG JPG 07500.02 (1 of 2) Wet well and valve vault
PDF DWG JPG 07500.02 (2 of 2) Wet well and valve vault
PDF DWG JPG 07500.03 (1 of 2) Sewage grinder unit (manhole installation)
PDF DWG JPG 07500.03 (2 of 2) Sewage grinder unit (manhole installation)
PDF DWG JPG 07500.04 (1 of 2) Sewage grinder unit (wet well installation)
PDF DWG JPG 07500.04 (2 of 2) Sewage grinder unit (wet well installation)
PDF DWG JPG 07500.05 (1 of 1) Electrical riser
PDF DWG JPG 07500.06 (1 of 1) Aluminum access hatch
PDF DWG JPG 07500.07 (1 of 1) Chain link fence & gate
PDF DWG JPG 07500.08 (1 of 1) Pump station access road
Section 08000 Storm Drainage
PDF DWG JPG 08000.01 (1 of 1) Standard yard inlet with concrete slab
PDF DWG JPG 08000.02 (1 of 1) Standard yard inlet with grate and frame
PDF DWG JPG 08000.03 (1 of 2) Standard concrete block or brick catch basin
PDF DWG JPG 08000.03 (2 of 2) Standard precast concrete catch basin
PDF DWG JPG 08000.04 (1 of 1) Standard median curb for catch basin (for use with 1'-6" curb & gutter)
PDF DWG JPG 08000.05 (1 of 1) Standard precast concrete manhole junction box
Section 10000 Project Identification
PDF DWG JPG 10000.01 (1 of 1) Project identification sign

Town Homepage