SECTION 09000 AS-BUILT CHECK LIST
All entities who construct public waterlines or facilities, public sanitary sewer lines or facilities, streets to be publicly maintained and private streets and travel lanes shall submit to the Town of Cary Engineering Department, certified as-built set of construction drawings and CD containing TIFF images of each sheet, signed and sealed by NCPE and/or NCPLS as a part of the Town’s acceptance process. As-builts must be submitted prior to acceptance of the improvements or issuance of a certificate of occupancy. The following check list must be attached to each set of as-builts submitted for approval. Each blank must be initialed by the applicant as being included on the as-builts or marked N/A if not applicable to the project. All plan sheets must be 24” X 36” mylar or vellum. Lettering shall be bold, clear and a minimum of 1/8” in height. All applicable information listed below must be included on all as-built drawings.
09010 AS-BUILT INFORMATION
TOC Plan #: _______________________
Submitted by: _______________________
Phone #: _______________________
Transmittal Date: _______________________
09020 DATA
Pg #
___ ___ A. Acreage in total tract
___ ___ B. Average lot size
___ ___ C. Total number of lots
___ ___ D. Total number of stop signs
___ ___ E. Total linear footage of infrastructure chart
_____ Streets (List individually in lengths: Public, Private or Fire Lane)
_____ Water mains (Identify size and length)
_____ Sewer mains (Identify size and length)
_____ Number of valves (For each size)
_____ Number of fire hydrants
_____ Number of manholes
_____ Other (Any additional appurtenances)
09030 GENERAL INFORMATION
Pg #
___ ___ A. Copy of recorded plat or deed of easements, indicating easements and
right of way
___ ___ B. Boundary of tract by courses and distance with references
___ ___ C. Tie to N.C. grid coordinate system
___ ___ D. 500 scale vicinity map
___ ___ E. Scale of drawings and bar scale
___ ___ F. North arrow
___ ___ G. Location of benchmark with M.S.L. elevations
___ ___ H. Seal and signature of North Carolina registered P.E. or P.L.S. on each
sheet that performed as-built
___ ___ I. All easements identified and dimensioned. Include legal reference
(deed, BOM, page #).
___ ___ J. Statement designating drawings are “as-built” on each sheet
09040 STREETS (Public, Private or Fire Lane)
Pg #
___ ___ A. Horizontal alignment with radii, P.C.’s, and P.T.’s of all curves
___ ___ B. Vertical alignment with centerline grades, vertical curve lengths and
station and elevation of all PVC’s and PVT’s and centerline profile.
___ ___ C. Dimensioned right of way and street widths
___ ___ D. Pavement section
___ ___ E. Typical cross section
___ ___ F. Horizontal and vertical sight lines
09050 STORM DRAINAGE
Pg #
___ ___ A. Outline of 100 year flood plain
___ ___ B. Pipe material
___ ___ C. Structure invert and top elevations
___ ___ D. Pipe size
___ ___ E. Pipe slope and distance
___ ___ F. Size of riprap dissipation pad
___ ___ G. Statement of stormwater velocity at all outlets
___ ___ H. Show permanent stormwater best management practice
___ ___ I. A separate, recorded easement dedication plat for utility extensions
outside right of way
09060 WATER SYSTEM
Pg #
___ ___ A. Pipe material labeled
___ ___ B. Pipe size labeled
___ ___ C. Separation from sanitary, storm sewer and gas line shown on plans
___ ___ D. Locations with distance references (permanent points/fixed structure)(2
each per appurtenance)
______ Valves
______ Fire hydrants
______ Blow-offs
______ Meters
______ Air release valves
___ ___ E. Certification by N.C.P.E. of construction in accordance with the water
extension permits
______ Certification on the plans
______ A separate certification sheet shall be provided
___ ___ F. A separate, recorded easement dedication plat for utility extensions
outside right of way
___ ___ G. Plan and profile
09070 SANITARY SEWER SYSTEM
Pg #
___ ___ A. Pipe material labeled
___ ___ B. Pipe size labeled
___ ___ C. Manhole top elevations
___ ___ D. Invert in and out elevations
___ ___ E. Pipe slope
___ ___ F. Separation from storm sewer, water line and gas line
___ ___ G. Locations with distance references (permanent points/fixed structure)(2
each per appurtenance)
______ Clean outs
______ Air release valves
______ Manholes
______ Force main valves
______ H. Horizontal control (angles at manholes)
___ ___ I. 100-year flood plain elevation
___ ___ J. Certification by N.C.P.E. of Construction in accordance with sanitary
sewer extension permits
______ Certification on the plans
______ A separate certification sheet shall be provided
___ ___ K. A separate, recorded easement dedication form for utility extensions
outside right of way
___ ___ L. Plan and profile
Town of Cary Use Only
------------------------------------------------------------------------------------------------------------------
Reviewed by: __________________________Date:_____________________
Approved: _____________________________Returned: __________________
END OF SECTION 09000