SECTION 09000      AS-BUILT CHECK LIST

 

All entities who construct public waterlines or facilities, public sanitary sewer lines or facilities, streets to be publicly maintained and private streets and travel lanes shall submit to the Town of Cary Engineering Department, certified as-built set of construction drawings and  CD containing  TIFF images of each sheet, signed and sealed by NCPE and/or NCPLS as a part of the Town’s acceptance process.  As-builts must be submitted prior to acceptance of the improvements or issuance of a certificate of occupancy.  The following check list must be attached to each set of as-builts submitted for approval.  Each blank must be initialed by the applicant as being included on the as-builts or marked N/A if not applicable to the project.  All plan sheets must be 24” X 36” mylar or vellum.  Lettering shall be bold, clear and a minimum of 1/8” in height.  All applicable information listed below must be included on all as-built drawings.

 

09010 AS-BUILT INFORMATION

 

Project Name:           _______________________

TOC Plan #:               _______________________

Submitted by:            _______________________       

Phone #:                     _______________________

Transmittal Date:       _______________________

       

09020 DATA

   Pg #

___ ___  A.  Acreage in total tract

___ ___  B.  Average lot size

___ ___  C.  Total number of lots

___ ___  D.  Total number of stop signs

___ ___  E.  Total linear footage of infrastructure chart

_____   Streets (List individually in lengths: Public, Private or Fire Lane)

_____   Water mains (Identify size and length)

_____   Sewer mains (Identify size and length)

_____   Number of valves (For each size)

_____   Number of fire hydrants

_____   Number of manholes

_____   Other (Any additional appurtenances)

 

09030 GENERAL INFORMATION                

        Pg #

___ ___  A.  Copy of recorded plat or deed of easements, indicating easements and

                     right of way

___ ___  B.  Boundary of tract by courses and distance with references

___ ___  C.  Tie to N.C. grid coordinate system

___ ___  D.  500 scale vicinity map

___ ___  E.  Scale of drawings and bar scale

___ ___  F.  North arrow

___ ___  G.  Location of benchmark with M.S.L. elevations

___ ___  H.  Seal and signature of North Carolina registered P.E. or P.L.S. on each

                     sheet that performed as-built

___ ___  I.   All easements identified and dimensioned. Include legal reference

                    (deed, BOM, page #).

___ ___  J.  Statement designating drawings are “as-built” on each sheet

 

09040 STREETS (Public, Private or Fire Lane)           

        Pg #

___ ___  A.  Horizontal alignment with radii, P.C.’s, and P.T.’s of all curves

___ ___  B.  Vertical alignment with centerline grades, vertical curve lengths and

                     station and elevation of all PVC’s and PVT’s and centerline profile.        

___ ___  C.  Dimensioned right of way and street widths

___ ___  D.  Pavement section

___ ___  E.  Typical cross section

___ ___  F.  Horizontal and vertical sight lines

 

09050 STORM DRAINAGE                    

        Pg #

___ ___  A.  Outline of 100 year flood plain

___ ___  B.  Pipe material

___ ___  C.  Structure invert and top elevations

___ ___  D.  Pipe size

___ ___  E.  Pipe slope and distance

___ ___  F.  Size of riprap dissipation pad

___ ___  G.  Statement of stormwater velocity at all outlets

___ ___  H.  Show permanent stormwater best management practice

___ ___  I.   A separate, recorded easement dedication plat for utility extensions

                    outside right of way

                                   

09060 WATER SYSTEM                

 Pg #

___ ___  A.  Pipe material labeled

___ ___  B.  Pipe size labeled

___ ___  C.  Separation from sanitary, storm sewer and gas line shown on plans

___ ___  D.  Locations with distance references (permanent points/fixed structure)(2

                    each per appurtenance)

______  Valves                    

______  Fire hydrants                     

______  Blow-offs

______  Meters                    

______  Air release valves 

 

 

 

___ ___  E.  Certification by N.C.P.E. of construction in accordance with the water

                   extension permits

______  Certification on the plans

______  A separate certification sheet shall be provided

___ ___  F.  A separate, recorded easement dedication plat for utility extensions

                    outside right of way

___ ___ G.  Plan and profile

                       

09070 SANITARY SEWER SYSTEM              

        Pg #

___ ___  A.  Pipe material labeled

___ ___  B.  Pipe size labeled

___ ___  C.  Manhole top elevations

___ ___  D.  Invert in and out elevations

___ ___  E.  Pipe slope

___ ___  F.  Separation from storm sewer, water line and gas line

___ ___  G.  Locations with distance references (permanent points/fixed structure)(2

                    each per appurtenance)

______  Clean outs             

______  Air release valves

______  Manholes               

______  Force main valves

______  H.  Horizontal control (angles at manholes)

___ ___  I.  100-year flood plain elevation

___ ___ J.  Certification by N.C.P.E. of Construction in accordance with sanitary

                   sewer extension permits          

______  Certification on the plans

______  A separate certification sheet shall be provided

___ ___  K.  A separate, recorded easement dedication form for utility extensions

                    outside right of way

___ ___  L.  Plan and profile                                                                      

 

 

 

 

 

Town of Cary Use Only

------------------------------------------------------------------------------------------------------------------

 

Reviewed by: __________________________Date:_____________________

Approved: ­_____________________________Returned: __________________

 

 

 

 

END OF SECTION 09000