|
TOWN OF CARY
,
NORTH CAROLINA
REQUEST
FOR REZONING
DATASHEET
|
|
Rezoning
Petition:
|
04-REZ-15
Cary
Park PDD
(Amendments to Tracts TC-1, MR-5, MR-6 and MR-7)
|
|
Land
Use Plan Amendment:
|
04-LPA-12 (Eliminating
minimum density requirement for Tracts MR-5, MR-6 and MR-7)
|
|
Meeting
|
Date
|
Recommendation
|
Action
|
|
Town Council
Public Hearing
|
September 9, 2004
|
Forward to
November 15, 2004
Planning Board meeting.
|
|
|
Planning and
Zoning Board
|
November 15, 2004
|
|
|
|
Town Council
|
December 9, 2004
|
|
|
|
APPLICANT
|
OWNERS
|
|
Jerry
Turner
Jerry
Turner and Associates, Inc.
905 Jones Franklin Rd
Raleigh,
NC
27606
Phone:
(919) 851-7150
Fax:
(919) 851-7547
Email:
jturner@jerryturnerassoc.com
|
Panther
Creek
Raleigh
LMTD
PRTNSHIP
190 Finley Golf Course Rd.
Chapel Hill, NC
27517-4473
Larry
E & Esther R Rigsbee
7641 Carpenter Fire Station Rd.
Cary, NC
27519-8619
James
E Britt & Mary Lorscheider
7629 Carpenter
Fire Station Rd.
Cary, NC
27519-8619
|
|
LOCATION
|
MAPS
&
DOCUMENTS
|
|
Cary
Park
is located east
of Green Level to
Durham
Road, north
and south of
Carpenter
Fire Station Road
and northeast of
Yates
Store Road.
|
Cary
Park Vicinity Map
Town of Cary Land Use Map
Town of Cary Zoning Map
Cary Park Master Land Use Map
|
|
PROJECT
DESCRIPTION
|
|
The request is to
amend the maximum amount of non-residential and residential
development allowed within Tract TC-1 on the Cary Park Planned
Development Master Plan. The
overall amount of commercial development would be reduced from
210,000 sq. ft. to 200,000 sq. ft.
The amount of Office development would be reduced from
170,000 sq. ft. to no more than 5% of the available commercial
square footage. The
request would also allow no more than 300 multi-family units within
tract TC-1. The request
also includes eliminating the minimum density allowed for tracts
MR-5, MR-6 and MR-7. Altering
the density range as proposed for tracts MR-5, MR-6 & MR-7 would
require an amendment to
Cary
’s Land Use Plan. See
attached Master Plan for further information.
The following modifications are proposed within the Cary Park
Planned Development:
|
|
Proposed
Modification:
|
Modification Description:
|
|
Adjustments to the
amount of commercial, office and residential development allowed
within Tract TC-1
|
Previously Approved
|
Proposed
Modification
|
|
210,000
sq. ft. of commercial
|
200,000
sq. ft. of commercial
|
|
17,000
sq. ft. of office
|
Min,
5% of commercial
|
|
185,000
sq. ft. of residential
|
300
dwelling units
|
|
Parcel
|
Maximum
Density (Du/Ac)
|
Acreage
|
Total
Units
|
Minimum
Lot
Size
|
|
portion
of 0735062027,
|
MR-5:
15 du/a
MR-6: 25 du/ac
MR-7:
8 du/ac
|
72.87
|
445
277
133
|
Front:
8’
Rear:
8’
Side:
6’
|
|
0725933654
|
|
26.01
|
300
(Multi-family
development proposed on combined acreage)
|
No
min. lot size proposed
|
|
0725941131
|
|
1.8
|
(part
of 300 units above)
|
|
|
0725944214
|
|
2.11
|
(part
of 300 units above)
|
|
|
Total
|
|
102.79acres
|
1,155
units
|
|
|
APPLICANT’S
JUSTIFICATION STATEMENT
|
|
This request is to
amend the TC-1 tract in the existing Cary Park PDD.
The request is the removal of office as a material component
of the TC-1 tract based on both short-term office demand issues and
long-term macro planning trends. On the short term demand
side, there clearly is an unmet need today for retail services in
Cary Park and there is not demand for new office construction
anywhere in the Triangle market much less the Cary Park area. Please
note that
Cary
’s office market is presently 23% vacant and even established
office parks such as Weston and
Regency
Park
are not engaged in new construction. On the long term planning
front;
Cary
Park
is clearly a tertiary office environment within the greater
Northwest Cary
sub-market and we feel that new demand for offices will be met first
by office product with immediate proximity to the
Research
Triangle
Park
and NC Highway 55. To
further support the proposed retail, 300 multi-family units are
proposed within TC-1. The
reduction in nonresidential square footages and the increase in
multi-family units will not require a new traffic study by the Town
of
Cary.
The request is to
also remove the minimum density requirement from Tracts MR-5, MR-6,
and MR-7. This change
will allow more flexibility in the product type provided.
The current minimum densities are: MR-5 at 10 du/ac, MR-6 at
15 du/ac, and MR-7 at 4 du/ac.
|
CURRENT
USE & ZONING
|
|
Current
Land
Use: Mixed
Use (MXD)
The
property is currently vacant.
|
Proposed
Land Use: Mixed
Use (MXD)
Proposed uses limited to commercial, office and multi-family
development.
|
|
Current
Zoning: Planned
Development District, Residential-40 (portion of)
|
Proposed
Zoning: Planned
Development District
|
|
ADJACENT
ZONING & LAND USES
|
|
|
Existing
Use
|
|
Existing
Land Use Designation
|
|
North:
|
Single-family
with some undeveloped frontage
|
Planned
Development District Major (with commercial, office &
residential use designations) and Residential-40 District.
|
MXD
(Mixed Use)
|
|
East:
|
High
density multi-family
|
Planned
Development District Major, with multi-family use designation
|
MXD
(Mixed Use) and MDR (Medium Density Residential)
|
|
South:
|
Vacant
|
Residential-40
District
|
PKS
(Park) and INS (Institutional) (Hawes Tract)
|
|
West:
|
Single-family
development
|
Planned
Development District Major, with single-family use designation.
|
INS
(Institutional) and LDR (Low Density Residential)
|
PLANNING
|
|
Comprehensive
Plan Analysis
|
The
site lies within an area designated as a
Community
Activity
Center
in the
Northwest Area Plan. The
proposal retains the Mixed Use (MXD) designation as described in the
Land Use Plan. However,
the proposed ranges of residential densities in MR parcels 5-7 are
unspecified, so a Land Use Plan amendment is required.
The proposal reduces the total combined non-residential
square footage for tracts TC-1, TC-2 and TC-3 from 780,000 to
610,000, and increases the number of multi-family residential units
from approximately 385 to 500, brining it closer to the ratio of
50-50 commercial and office/institutional, and the suggested
standard of 1 multifamily housing unit per 1,000 square feet of
non-residential floor space.
|
|
Open
Space Considerations
|
The
site is predominantly wooded in mixed hardwood-conifer forest, with
a 3-acre stand of conifers at the southwestern corner.
There are no historic resources identified on the site based
on the Town’s Open Space Master Plan.
|
|
Parks
and Greenways
|
The Northwest Area
Plan shows a 400’ open space corridor along Morris Branch, along
the northern boundary of MR-6 and the southern boundaries of MR-5
and MR-7.
|
|
Transportation
Planning
|
The
Comprehensive Transportation Plan includes a 6-lane median divided
section for Green Level to
Durham Rd.
, a 4-lane
median divided section for
Carpenter Fire
Station Rd.
and a 3-lane
section for
Cary Glen Blvd.
The
applicant is proposing right-in/right-out access along both Green
Level to
Durham Rd.
and
Carpenter Fire
Station Rd.
The applicant
is proposing sidewalks on both sides of all streets with the
exception of single-loaded streets with development on one side and
cul-de-sacs. This location is within the C-Tran service area, a
transit stop is proposed along
Cary Glen Blvd.
|
|
School
Information
|
Cary
Park
previously
entered into an agreement with the Town of
Cary
and Wake County
School System, whereby Cary
Park
is to provide a
lump sum contribution to offset anticipated School impacts.
The Wake County School System would use the funds collected
to construct new schools in the area of
Cary
Park.
|
|
ENGINEERING
|
|
Environmental
Considerations
|
The
project is located in the Jordan Lake Watershed and will have to
meet the requirements of the Reservoir Watershed Protection
Ordinance of the Town of
Cary
.
The
project will be required to meet the nitrogen requirements of the
Town of
Cary
.
There
are riparian buffers associated with this project.
|
|
Utilities
(Water and Sewer)
|
This
project will have access to public water and sewer by connecting to
existing systems within Cary Park PUD.
|
|
Traffic
Impact Analysis
|
The
revised TC-1 proposed is a reduction in trips generated. No
traffic Impact Study required.
|
|
|
Average
Daily Traffic
|
Morning
Peak
Traffic
|
Evening
Peak
Traffic
|
|
|
Existing
Approved TC-1
|
12,111
|
576
|
1153
|
|
|
Proposed
TC-1
|
10,254
|
364
|
912
|
|
PARCEL
& OWNER INFORMATION
|
|
Property
Owner(s)
|
County
Parcel
Number
|
Real
Estate ID(s)
|
Area
(Acres)
|
|
Panther Creek
Raleigh
LMTD PRTNSHIP
190 Finley Golf Course Rd.
Chapel Hill
,
NC
27517-4473
|
0725933654, portion
of 0735062027
|
0289290, portion of
0266895
|
26.01
72.87
|
|
Larry E &
Esther R Rigsbee
7641 Carpenter Fire Station Rd.
Cary,
NC
27519-8619
|
0725941131
|
0159970
|
1.8
|
|
James E Britt &
Mary Lorscheider
7629 Carpenter Fire Station Rd.
Cary,
NC
27519-8619
|
0725944214
|
0008491
|
2.11
|
|
|
|
|
|
|
Total
Acreage
|
102.79
acres
|
|